Station Automation COM600
COM600 3.3

Operator's Manual

Содержание COM600 series

Страница 1: ...Station Automation COM600 COM600 3 3 Operator s Manual...

Страница 2: ......

Страница 3: ...e COM600 computer 13 3 5 Substation and communication structures 13 3 5 1 Substation structure 13 3 5 2 Communication structure 15 3 6 Single Line Diagram 16 3 6 1 General about Single Line Diagram 16...

Страница 4: ...ter setting 31 3 11 1 Changing parameters 31 3 12 Measurements 33 3 12 1 Viewing measurements 33 Appendix 1 35 Single Line Diagram symbols 35 Appendix 2 39 Quality values in Event and Alarm Lists 39 I...

Страница 5: ...s furnished under a license and may be used copied or disclosed only in accordance with the terms of such license Copyright 2006 ABB All rights reserved Trademarks 1 2 ABB is a registered trademark of...

Страница 6: ...re used for the name of a keyboard key that is not labeled on the keyboard For example the space bar comma key and so on Press CTRL C indicates that you must hold down the CTRL key while pressing the...

Страница 7: ...ality and timestamp Event A physical IEC 61850 device that behaves as its own commu nication node in the IEC 61850 protocol Intelligent Electronic Device Series of standards specifications aiming at o...

Страница 8: ...870 5 101 Slave OPC 1MRS756703 IEC 60870 5 101 Master OPC 1MRS752278 IEC 60870 5 103 Master OPC 1MRS755384 IEC 60870 5 104 Slave OPC 1MRS756704 IEC 60870 5 104 Master OPC 1MRS755321 IEC 61850 Master O...

Страница 9: ...rther used to transfer information to a network control centre NCC or distributed control system DCS COM600 benefits from the potential of the IEC 61850 standard by using the IEC 61850 6 substation co...

Страница 10: ...le Line Diagram view Events Shows the events list Alarms Shows the alarms list Data historian Shows the data historian information Optional feature Help Shows the HMI help Logout Predefined user accou...

Страница 11: ...eter set ting X X X view Disturbance recording X X X view System supervi sion X Access enabled 1 Can change own password view View only Operating system access permissions using local browser If enabl...

Страница 12: ...w users 3 3 2 The administrator can add users in the Add User window To add a new user 1 Click the Users tab on the left 2 Select Add User 3 Type in a new user name The length of the user name can be...

Страница 13: ...ply To change your own password 1 Click the Settings tab on the left 2 Click Change password 3 Type in the old password 4 Type in a new password and confirm it 5 Click Apply Connecting HMI to the COM6...

Страница 14: ...look at a list of events click View Events above the Persisting Alarms list IED information By clicking the IED objects you can view their communication status and information on diagnostic counters B...

Страница 15: ...ew jpg Figure 3 5 2 1 The communication view to HMI Device and diagnostics information By clicking the computer name at the top of the structure the device information such as the hardware and softwar...

Страница 16: ...intervals A sample SLD is shown in Figure 3 6 1 1 SLD_example png Figure 3 6 1 1 An example of the Single Line Diagram The Single Line Diagram symbols are explained in detail in Appendix 1 Single Lin...

Страница 17: ...e control direction by clicking Open or Close 2 Click Operate to activate the selection or Cancel to cancel the operation Some of the buttons can be disabled depending on the state of the switch It is...

Страница 18: ...gear The Three state switch can be closed main disconnector closed opened and earthed earth disconnector closed It is not possible to go directly from closed to earthed state or the other way around t...

Страница 19: ...s blocked from open and close control from remote or local HMI If Hot Line Tag is applied to Tap changer raising and lowering and operation modes are disabled To apply Hot Line Tag 1 Open Switch Devic...

Страница 20: ...ck Apply to apply Hot Line Tag Hot_Line_Tag bmp Figure 3 6 3 1 1 Applying the Hot Line Tag To remove the Hot Line Tag 1 Open Switch Device Control Dialog by clicking the object on the single line dia...

Страница 21: ...to the Caption text box 4 Enter a description of the Information Tag 5 Click Apply to apply the Information Tag Information_Tag bmp Figure 3 6 3 2 1 Applying the Information Tag To remove the Informat...

Страница 22: ...ring a numeric value You must have the required user permissions to perform these changes and local remote switch must allow the operation The tap changer must also be in manual operating mode The Ope...

Страница 23: ...indicate the status of busbar sections in several different ways It can indicate which busbar sections are powered unpowered or in certain other states or which voltage level each busbar section has s...

Страница 24: ...ons depends on the voltage source Alarms 3 7 General about alarms 3 7 1 The Alarm List displays a summary of the present alarm situation of the supervised process Each alarm is presented as an alarm t...

Страница 25: ...ge level or bay with the Filter function In the Persisting alarms list you can see active alarms The Fleeting alarms list displays a list of inactive unacknowledged alarms The alarm list is continuous...

Страница 26: ...iltering alarms 3 7 4 Filters can be used when you want to display only specific information To filter alarms 1 Click Filter in the toolbar of the Alarms view A window displaying the substation struct...

Страница 27: ...endix 2 Quality values in Event and Alarm Lists Monitoring and handling events 3 8 2 You can monitor the events of the substation by clicking Events in the command bar at the top of the screen To moni...

Страница 28: ...tion To filter events 1 Click Filter in the toolbar of the Events view A window displaying the substation structure opens 2 Click the object whose events you want to view Now the Events list displays...

Страница 29: ...ta historian can be used for accurate process performance monitoring by following process and equipment performance calculations with real time and history values Better understanding of the process b...

Страница 30: ...bance recordings 3 10 1 Most of the IEDs are equipped with a Disturbance recording function that locally stores the values of currents voltages frequencies and binary signals in a disturbance file bef...

Страница 31: ...erts the current selection as follows If no recordings are selected Selects all recordings If all recordings are selected Unselects all recordings If some recordings are selected Unselects them and se...

Страница 32: ...IED has been configured with a store option a store dialog opens In the dialog you can store the parameter changes permanently to the IED non volatile memory If you click OK the parameter changes are...

Страница 33: ...Enable Write on the top of the Parameter Setting view 3 Enter the new values for the parameters 4 Write the changed parameter values to IED by clicking Write to IED 5 Store the parameter changes perm...

Страница 34: ...measurements png Figure 3 12 1 1 An example view of measurements 34 1MRS756705 Station Automation COM600 COM600 3 3 Operator s Manual...

Страница 35: ...tic manual X not X and so on It can also be used to send a command Two State Switch Hyperlink to external information source such as a web page or a local file on COM600 Files should be stored under C...

Страница 36: ...sition Disconnector Open position Disconnector Closed position Disconnector Bad faulty position Truck Intermediate position Truck Open position Truck Closed position Truck Bad faulty position Three St...

Страница 37: ...as individual sym bols Power Transformer with two Windings and Tap Changer Primary winding on top Second ary winding below left Tertiary winding below right All compos ing elements exist as individual...

Страница 38: ...ent ation IEC rep resenta tion ANSI rep resenta tion Description Out feeder Earth symbol Bay Switch Indicator Station Switch Indicator Display Voltage 38 1MRS756705 Station Automation COM600 COM600 3...

Страница 39: ...L OperatorBlocked OoR OutOfRange OSC Oscillatory NT OldData NC Inconsistent NA Inaccurate OV Overflow BadRef BadReference IV Failure BadTime BadTime SubNormal SubNormal CfgErr ConfigError NotConn NotC...

Страница 40: ...40...

Страница 41: ...l 23 modes 24 C communication structure 15 D Data Historian 29 device information 15 diagnostics information 15 disturbance recordings 30 E event information 14 events filtering 26 28 general 27 H Hot...

Страница 42: ...lag 39 S Single Line Diagram general 16 symbols 35 substation structure 13 Switch Device Control 16 T tap changer 22 U users adding 12 change group 13 change password 13 modifying properties 12 42 1MR...

Страница 43: ......

Страница 44: ...B Inc ABB Oy 655 Century Point Distribution Automation Lake Mary Florida 32746 P O Box 699 USA FI 65101 VAASA FINLAND Tel 1 407 732 2000 Tel 358 10 22 11 Fax 1 407 732 2335 Fax 358 10 224 1094 www abb...