Maintenance-Object Repair Procedures
555-233-143
8-164
Issue 1 May 2002
Layer 1 Transmission Error Counter Test (#624)
This test reads and clears the BRI port’s Layer 1 Transmission error counter
maintained on the ASAI circuit pack. This counter is incremented by the circuit
pack when it detects a Layer 1 transmission problem. The test passes if the value
of the counter is 0 (that is, the error is cleared). If the counter is not zero, the test
fails, and the value of the counter is displayed in the Error Code field.
This error is most likely due to a problem with the wiring or adjunct (verify that the
wiring meets the configuration rules defined in DEFINITY Communications
System Generic 1 and Generic 3i Wiring, 555-204-111). It does not indicate a
problem with the TN800 circuit pack. This test is useful for verifying the repair of
the problem.
Table 8-64.
Test #624 Layer 1 Transmission Error Counter Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Response was not received from the circuit pack within the allowable time
period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack using the
busyout board UUCSS and reset board UUCSS commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The TN800 circuit pack is still detecting errors of this type. The Error Code field
contains the value of this counter.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, review the results of other tests in the long test
sequence. Note the results of the Level 1 Status Inquiry test. Follow the
repair procedures for any of the executed tests if they fail. Otherwise, go to
the next step.
3. Replace the circuit pack.
PASS
The Layer 1 Transmission error counter was read correctly and has a value of
0.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...