![Avaya S8700 Series Скачать руководство пользователя страница 1277](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021277.webp)
DIG-LINE (Digital Line)
Issue 1 May 2002
8-555
555-233-143
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out of service due to
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, repeat
test at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port. Use status station or status attendant to
determine the service state of the port. If the port is in use, wait until it is
idle before testing. Attendants are always in use (off-hook) if the handset
is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on primary channel. In some cases, users may not
notice disruption in service. In extreme cases, conferencing feature may not
work at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may range
from noticing nothing to not being able to use this port.
Table 8-223.
Test #13 Voice and Control Channel Local Loop Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...