![Avaya S8700 Series Скачать руководство пользователя страница 2590](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022590.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1868
Issue 1 May 2002
Technician-Demand Tests: Descriptions and Error
Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
NPE Crosstalk Test (#6)
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected
time slot, and does not cross over to time slots reserved for other connections. If
the NPE is not working correctly, 1-way and noisy connections may be observed.
This test is usually part of a port’s long test sequence and takes 20 to 30 seconds
to complete
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6)
X
ND
Conference Circuit test (#7)
X
ND
Port Audit and Update test (#36)
X
X
ND
Table 8-717.
Test #6 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use the status access-endpoint extension or command
to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...