Maintenance-Object Repair Procedures
555-233-143
8-1056
Issue 1 May 2002
If the circuit pack has an entry in the circuit plan and either of the other two
conditions are not met, a MINOR alarm is logged. To resolve the error,
either:
1. Make sure the circuit pack is properly administered and that a
functioning MAPD circuit pack is inserted in the correct slot
or
Completely remove the MAPD-BD from the system:
‘‘Shutting Down NT on the TN802’’
b. Remove any administered DS1 trunks, access endpoints, or
PRI endpoints associated with the circuit pack from their
respective trunk groups.
c. Remove the DS1 (remove ds1 UUCSS) and circuit pack
(change circuit pack UUCSS) administration.
If the circuit pack is properly administered and the red LED is still on, follow
the instructions for LED Alarms with Error Type 1 in Chapter 7.
b. Error Type 2—NT is down and the system attempts to reset the board. If
the reset fails, the board is probably bad.
1. Replace the circuit pack.
c. Error Type 18—The circuit pack has been busied out.
1. Release the board (release board UUCSS).
d. Error Type 23 and 1025: The MAPD-BD circuit pack is not completely
administered. In addition to insertion, the MAPD circuit pack must have all
of the following administration:
■
Have an entry in the circuit plan (change circuit pack)
■
Be administered as DS1 (add ds1 UUCSS)
The MAPD circuit pack differs from others in that inserting it into the switch
backplane is not enough to make the board usable.
e. Error Type 125, no Aux Data:—A wrong circuit pack is inserted in the slot
where this circuit pack is logically administered. To resolve this problem,
either:
1. Remove the wrong circuit pack and insert the logically administered
circuit pack
or
Re-administer this slot (change circuit-pack) to match the circuit
pack inserted.
f. Error Type 257—This error is associated with the Common Port circuit
pack maintenance test. See
‘‘XXX-BD (Common Port Circuit Pack)’’ on
for details.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...