TIE-TRK (Analog Tie Trunk)
Issue 1 May 2002
8-1641
555-233-143
Notes:
a. Digit time-out. This occurs when the far-end PBX began transmitting digits
too late (10 seconds) after receiving the signal indicating ready to receive
digits (if any). This can occur on an incoming immediate, wink, or delay
dial line. Check the far-end PBX to ensure a translation match at both
ends. This error does not apply to TN497.
b. Rotary dial before wink. This occurs when the far-end PBX starts dialing
before the PBX sends the wink on a wink-start or delay-dial trunk. Check
the far-end PBX to ensure a translation match at both ends. This error
does not apply to TN497.
c. Rotary dial too early. This occurs when the far-end PBX starts dialing too
soon (about 50ms) after seizure on a wink start or delay dial line. Check
the far-end PBX to ensure a translation match at both ends. This error
does not apply to TN497.
d. On hook before wink. This occurs when the far end goes on hook before a
wink. Check the far-end PBX to ensure a translation match at both ends.
This error applies only to TN439.
e. On an outgoing wink-start or delay-dial trunk, the wink time was too short
(less than 80ms) for a valid signal. Check the far-end PBX to ensure a
translation match at both ends. This error does not apply to TN497.
f. This is a software audit error that does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors (if any).
g. This indicates that the trunk in question has been busied-out by
maintenance personnel.
h. The circuit pack has been removed or has been insane for more than
11 minutes. To clear the error, reinsert or replace the circuit pack. TN439
does not alarm this error. This error does not apply to TN497.
i. The rotary dial rate was too slow — less than 8 pulses per second. Check
the far-end PBX to ensure a translation match at both ends.
j. The rotary dial rate was too fast — above 12 pulses per second. Check the
far-end PBX to ensure a translation match at both ends.
k. The time between digits was too short (less than 300ms). Check the
far-end PBX to ensure a translation match at both ends.
l. These errors do not apply to TN439 and TN497.
m. This indicates that the trunk is still seized with an incoming call. The
far-end PBX is not releasing the trunk after the call was dropped. Check
the far-end PBX for problems.
Once the trunk is released from the call, the severity of this problem is
decreased. If Error Type 1025 does not appear again, this means that the
problem has been corrected. Verify that Error Type 1025 does not
reappear in the Error Log.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...