Maintenance-Object Repair Procedures
555-233-143
8-1188
Issue 1 May 2002
Conference Circuit Test (#7)
One or more Network Processing Elements (NPEs) reside on each circuit pack
with a TDM-bus interface. (The TN464 UDS1 circuit pack has one SCOTCH-NPE
chip instead of several NPE chips). The NPE controls port connectivity and gain,
and provides conferencing functions on a per-port basis. The Conference Circuit
test verifies that the NPE channel for the port being tested can correctly perform
the conferencing function. The NPE is instructed to listen to several different
tones and conference the tones together. The resulting signal is then measured
by a Tone Detector port. If the level of the tone is within a certain range, the test
passes.
Table 8-486.
Test #7 Conference Circuit Test
Error
Code
Test
Result
Description / Recommendation
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
in use on a valid call. Use the status station or status trunk command to
determine when the port is available for testing.
1002
ABORT
The test was aborted because the system could not allocate time slots for the
test. The system might be under heavy traffic conditions, or it might have time
slots out of service due to TDM-BUS errors. (The status health command
may be used to determine whether the system is experiencing heavy traffic.)
1. If the system has no TDM-BUS errors, is not handling heavy traffic, and the
port status is idle, retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present or some of the tone
detectors may be out of service. Issue the list measurements tone-receiver
command to display basic information about the system’s tone receivers.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals up to 5 times.
1004
ABORT
The port has been seized by a user for a valid call. Use status station or
status trunk command to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1018
ABORT
The test was disabled via translation.
1. You may want to determine why the test has been disabled before you
enable it.
2. To enable the test for the particular analog station being tested, enter the
change station extension command, and then change the
Test
field on
the Station form from n to y.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...