RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1339
555-233-143
Station Present Test (or Ringing Application Test)
(#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether the terminal equipment is
connected to the port. The test may cause some terminal equipment to ring
briefly during daily maintenance. If this ringing disturbs the customer or the
terminal equipment, disable it via the
Tests
field on the change station form.
However, on some software releases, Test #35 is disabled.
Table 8-542.
Test #48 Station Present Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port UUCSSpp command to determine
the station extension. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in use.
Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test, and the test was aborted.
Use the display port UUCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the service state indicates that the port is in use. Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008
ABORT
Could not allocate a ringing circuit. Either every ringing circuit is in use, or the
ringing generator is either defective or incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log. If
an ABORT 1008 occurs for this test on other circuit packs as well, then the
ringing generator may be defective or incorrectly wired (see errors for
RING-GEN). If it does not occur on other ports, then all four ring phases
are in use.
1018
ABORT
The test has been disabled by administration. The default for the
Test
field
on the change station form is
y
. Determine why this field has been set to
n
on
this station (this may be due to the brief ringing disturbance that this test may
cause).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the
Test?
field on the change
station form to
y
.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...