Maintenance-Object Repair Procedures
555-233-143
8-1638
Issue 1 May 2002
TIE-TRK (Analog Tie Trunk)
NOTE:
Many trunk problems are caused by incorrect settings of parameters on the
trunk group administration form. Settings must be compatible with the local
environment and with parameter settings on the far end. The Application
Notes section of that book shows the correct settings for administrable
timers and other parameters on a country-by-country basis.
The following circuit packs, including every suffix such as TN760D, support
analog tie trunks:
Each tie trunk circuit pack occupies a port circuit pack slot and contains 4 port
circuits. Each port circuit supports 1 analog tie trunk used to connect the switch to
another PBX across 1- or 2-way dedicated circuits (see preceding list).
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to
Run
12
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides
(01–21). pp is the 2-digit port number (01, 02,...).
2.
If ATMS testing is enabled, check the error log for ATMS errors 3840 and 3841. If the error log
indicates that measurements exceeded acceptable thresholds, and no other trouble is found
with test trunk, run the ATMS test call with test analog-testcall port UUCSSpp full.
Full Name of MO
TIE-TRK
MAJOR
3
3.
A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by the set
options command and that at least 75 percent of the trunks in this trunk group are alarmed.
This alarm does not apply to TN497.
test port UUCSSpp l
Tie Trunk
TIE-TRK
MINOR
test port UUCSSpp l
Tie Trunk
TIE-TRK
WARNING
test port UUCSSpp sh
Tie Trunk
Table 8-636.
Analog Tie Trunk Circuit Packs
Code
Trunk Type
Signaling Leads
TN760
4-wire
E&M
TN437
4-wire
E&M
TN439
2-wire
A&B (2-way circuits only)
TN458
4-wire
E&M
TN497
2-wire
A&B
TN2140
4-wire
E&M
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...