S-SYN-PT (Speech Synthesis Port)
Issue 1 May 2002
8-1369
555-233-143
Speech Synthesis DTMF Receiver Test (#163)
A series of dual-tone multifrequency (DTMF) tones are conferenced from the TDM
bus into the port’s DTMF receiver and checked to see if the correct tones have
been detected during the correct intervals. If every DTMF tone was detected
correctly, the test passes. If any of the tones were not detected correctly, the test
fails.
Table 8-558.
TEST #163 Speech Synthesis DTMF Receiver
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call and therefore unavailable for certain tests. Wait until the
port is idle (amber LED is off) before retesting.
1. If the port is idle, retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
DTMF tones were not detected. This type of failure may cause features using
touch-tone input to the Speech Synthesis port to malfunction.
1. Verify that the Tone-Clock circuit is functioning correctly by checking the
Error Log and using the test tone-clock long command.
2. If the test fails again, replace the Speech Synthesis circuit pack.
PASS
The port has detected every DTMF tone correctly. User-reported troubles
should be investigated using other tests and by verifying other ports on this
circuit pack are working correctly.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...