FIBER-LK (Fiber Link)
Issue 1 May 2002
8-831
555-233-143
The following terms are used in the error descriptions:
LEDs for Circuit Packs on a Fiber Link
The amber LEDs on the three types of boards, SNI (TN573), EI (TN570), and DS1
Converter (TN574 or TN1654), that may be a part of the fiber link can help in
diagnosing problems with the fiber link. The amber LED states are as follows.
The flashing LED patterns take precedence over the active or standby LED
patterns.
If both endpoints of a fiber link (EI and/or SNI) are flashing with a fiber out of frame
pattern, a fast amber LED pattern (0.1 second on and 0.1 second off), check the
lightwave transceivers (if present). Both lightwave transceivers on the fiber link
must be of the same type. The 9823a shortwave transceiver and the 9823b
longwave transceiver must never be combined on the same fiber link because a
fiber out-of-frame condition will exist. The 9823a lightwave transceiver should be
used for distances up to 4900 feet and the 9823b lightwave transceiver should be
used for distances up to 25,000 feet.
Control Path
The path between the two fiber endpoints that is necessary for the
two endpoint circuit packs to communicate.
Circuit Path
The path between the two fiber endpoints that is necessary for
circuit switched phone calls to work.
Neighbor
The circuit pack on the other end of the fiber.
Out of Frame
A circuit pack reports fiber out of frame if it cannot detect valid data
coming from the fiber.
Packet Path
The path between the two fiber endpoints that is necessary for
packet-switched messages to be sent between the two fiber
endpoints.
Table 8-316.
SNI Amber LED Flashing Codes
Condition
LED on
LED off
Fiber out of Frame
0.1 second
0.1 second
In Frame, No Neighbor
1
1.
The fiber is in frame, but no communication exists to the neighbor
0.5 second
0.5 second
SNI active
Solid on
Never off
SNI standby
Never on
Solid off
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...