![Avaya S8700 Series Скачать руководство пользователя страница 2577](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022577.webp)
VC-DSPPT
Issue 1 May 2002
8-1855
555-233-143
Table 8-710.
Test #1105 VC-DSP Port DSP Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available, or the port is busy
with a valid call.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test, the traffic load on the
system is very high, or time slots are out-of-service due to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a Tone Detector for the test, the system is
oversized for the number of Tone Detectors present, or some Tone Detectors
are out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port has been seized by a user for a valid call. Use the status station
command for the station associated with this port and determine whether the
port is available for testing
1. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received from the VC-BD circuit pack
within the allowable time period.
1. If this result occurs repeatedly, reset the circuit pack if the other ports are
idle by using the busyout port UUCSSpp and reset port UUCSSpp
commands.
2. If this result occurs again, replace the circuit pack.
2012
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
0, 1
FAIL
The VC-DSPPT DSP Loopback test failed.
1. Replace the circuit pack.
PASS
The VC DSPPT DSP Loopback test passed
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...