![Avaya S8700 Series Скачать руководство пользователя страница 1569](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021569.webp)
FIBER-LK (Fiber Link)
Issue 1 May 2002
8-847
555-233-143
108
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped SNI
in slot 8. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1537, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1537, replace the
SNI in slot 8.
109
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the equipped SNI
in slot 9. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1793, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1793, replace the
SNI in slot 9.
112
FAIL
The SNI circuit pack (Endpoint 1) cannot communicate with the active SNC.
(The list fiber-link command displays a fiber link’s endpoints.)
1. Check the error log for other SNI circuit packs in the same carrier with a
257 SNI-BD error. Use display errors with category PNC to view SNI-BD
errors. If other SNI circuit packs in the same switch node carrier have
Error 257, then replace the active SNC in this switch node carrier.
Replacing an SNC may be service interrupting. Refer to the SNC-BD
section for the procedure for replacing an SNC.
2. Replace this SNI.
3. Replace the active SNC in the same switch node carrier.
Table 8-328.
Test #759 Configuration Audit —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...