Maintenance-Object Repair Procedures
555-233-143
8-852
Issue 1 May 2002
140
FAIL
The Endpoint 1 SNI is physically connected to a DS1 CONV but is not
administered to be connected to a DS1 CONV. (The list fiber-link command
displays a fiber link’s endpoints.) Either add the DS1 converter complex to the
fiber that this SNI is associated with by:
1. Check for the fiber that this SNI is an endpoint of by checking list
fiber-link.
2. Remove fiber-link for the fiber that this SNI is an endpoint of.
3. Add the fiber back via add fiber-link and this time administer the DS1
converter complex also. Or, remove the DS1 CONV connection and
connect the SNI directly to its administered fiber endpoint by entering list
fiber-link and verifying that the fiber-optic and metallic cable connections
are installed as administered.
202
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 2. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 1, replace the SNI being
tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 1, replace the SNI in
slot 2.
203
FAIL
The SNI circuit pack (Endpoint 2) cannot communicate with the equipped SNI
in slot 3. (The list fiber-link command displays a fiber link’s endpoints.)
1. Perform the
‘‘Fault Isolation for Fiber Links’’ on page 4-19
. This should
resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER Error Type 257, replace the SNI
being tested. (Replacing an SNI may be service interrupting. Refer to the
SNI-BD section for the procedure to replace an SNI.) To view SNI-PEER
errors, use the display errors command with category PNC-PEER. Retry
the command.
3. If the SNI being tested still has SNI-PEER Error Type 257, replace the SNI
in slot 3.
Table 8-328.
Test #759 Configuration Audit —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...