![Avaya S8700 Series Скачать руководство пользователя страница 1716](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021716.webp)
Maintenance-Object Repair Procedures
555-233-143
8-994
Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. These Error Types indicate a disagreement between this switch and the
switch at the other end of the trunk connection with regard to the ISDN call
state of the DS1 ISDN Trunk. This switch will automatically try to recover
by clearing the call, (that is, call will be torn down). You can use the status
trunk group#/member# command to determine the state of the trunk.
Table 8-392.
DS1 ISDN Trunk Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp
1 (a)
Any
None
test port UUCSSpp
15 (b)
Any
Audit and Update test
(#36)
18
0
busyout trunk
grp/mbr
release trunk grp/mbr
19 (c)
0
None
129 (d)
None
WARNING
OFF
test port UUCSSpp
130 (e)
None
WARNING
ON
test port UUCSSpp
257 (f)
Any
None
test port UUCSSpp
513 (g)
Any
None
WARNING
OFF
test port UUCSSpp
769 (f)
Any
None
test port UUCSSpp
1025 (h)
0
None
1281
Any
Conference Circuit test
(#7)
MAJOR MINOR
WARNING
2
2.
Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON
test port UUCSSpp l r 4
1537
Any
NPE Crosstalk test
(#6)
MAJOR MINOR
WARNING
ON
test port UUCSSpp l r 3
1793 (i)
Any
None
test port UUCSSpp
3073 (j)
Any
Service State audit
(#256)
test port UUCSSpp
3585 (k)
Any
None
none
3841 (l)
Any
None
WARNING
OFF
None
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...