DIOD-TRK (DIOD Trunk)
Issue 1 May 2002
8-575
555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors that have no specific test associated with them.
See
for an explanation and appropriate action.
b. This is a software audit error and does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors.
Table 8-232.
DIOD Trunk Error Log Entries
Error Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port sh
15 (b)
any
Port Audit Update test (#36)
18
0
busyout trunk grp/mbr
WARNING
release trunk
769 (a)
57392
None
MAJOR
MINOR
WARNING
2
2.
Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is upgraded to a
Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON
1537
Dial Tone test (#0)
MAJOR
MINOR
WARNING
ON
test port long r 2
1793
Looparound and Conference
test (#33)
MAJOR
MINOR
WARNING
ON
test port long r 3
2049
NPE Cross Talk test (#6)
MAJOR
MINOR
WARNING
ON
test port long r 3
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...