![Avaya S8700 Series Скачать руководство пользователя страница 980](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102980.webp)
Maintenance-Object Repair Procedures
555-233-143
8-258
Issue 1 May 2002
3890
A request to use a network
service (for example, SDN)
has been denied.
Administration somewhere
in the network has indicated
that the requested service
has not been subscribed to
or purchased for this trunk.
This could indicate
■
a local administration problem
■
a mismatch between the local administration and that
of the network provider.
1. From the circuit pack and port number (in the Aux
Data field), determine the trunk group against which
the error was reported.
2. Display the trunk group form.
If the trunk group is Call-by-Call (the
Service
Type
field is
cbc
), check every routing pattern form
containing this trunk group to see if the
Service/Feature fields contain the correct network
services purchased for this trunk.
If the trunk group is not Call-by-Call, check that the
Service Type
field contains the single network
service purchased for this trunk.
3. If local administration appears correct, consult with
the customer and/or the network provider to
determine the services that the customer has
subscribed to for this trunk group.
3892
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
1. If customer is complaining of unexpected intercept
tones when accessing ISDN trunks or PRI endpoints
and no other cause can be found, escalate the
problem and provide the next tier with this Error Log
information.
3894
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
1. Eliminate any transitory state mismatch problems
(test port UUCSSpp for the trunk port shown in the
Aux Data field). Test #256 (Service State Audit) is the
important test in the sequence.
2. If Test #256 passes yet the customer continues to
complain of unexpected intercept tones when
accessing ISDN trunks or PRI endpoints and no other
cause can be found, escalate the problem and
provide the next tier with this Error Log information.
3905
Protocol detail; may offer a
clue if customer is having
ISDN calls denied with an
unexpected intercept tone.
1. If customer is complaining of unexpected intercept
tones when accessing ISDN trunks or PRI endpoints
and no other cause can be found, escalate the
problem and provide the next tier with this Error Log
information.
Table 8-106.
Descriptions and repair recommendations (Error Types 3840-3928)
—
Continued
Error
Code
Description
Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...