Maintenance-Object Repair Procedures
555-233-143
8-1690
Issue 1 May 2002
Tone Generator Crosstalk Test (#90)
This test checks the ability of the Tone Generator to talk on a specific time slot.
The tone generator is told to talk on a specific time slot. The other idle time slots
are checked to make sure the Tone Generator put the tone on only the specified
time slot.
Table 8-655.
Test #90 Tone Generator Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
None
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABORT
The system was not able to put the tone generation facility in the appropriate
mode to test it.
1002
ABORT
The system could not allocate time slots for the test connection. This can
happen when the system is heavily loaded. If the system is not heavily loaded,
then test the TDM-BUS via the test tdm port-network PN# command.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The Tone Generator could be defective. In a port network with more than one
IPSI or Tone-Clock circuit pack, the system will attempt to move the tone
generation function to the alternate one.
1. Test the IPSI or Tone-Clock circuit pack again via the test tone-clock UUC
command.
2. If the test fails again, look at the Hardware Error Log for Tone Detector
circuit pack errors.
3. If there are Tone Detector circuit pack errors, see Tone Detector
maintenance documentation (
‘‘DTMR-PT (Dual-Tone Multifrequency
‘‘GPTD-PT (General-Purpose Tone Detector Port)’’
,
‘‘CLSFY-PT (Call Classifier Port)’’
‘‘ETR-PT (Enhanced Tone Receiver
to resolve these errors first.
4. If there are no Tone Detector circuit pack errors, then the IPSI or
Tone-Clock circuit pack should be replaced. See
.
PASS
The tone generation facility is able to put tones out.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...