![Avaya S8700 Series Скачать руководство пользователя страница 914](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102914.webp)
Maintenance-Object Repair Procedures
555-233-143
8-192
Issue 1 May 2002
1793 (n)
13
None
MIN
ON
2049 (o)
15
None
MIN
OFF
test board UUCSS r 4
2050 (o)
Expansion Interface Lock
Query test (#304)
MIN
OFF
test board UUCSS r 4
2305 (p)
None
MIN
ON
2309 (p)
Packet interface test
(#598)
MIN
ON
test board UUCSS r 2
2561 (q)
Expansion Interface 2-way
Transmission test (#241)
MAJ
OFF
test board UUCSS r 3
2817 (r)
Any
ATM Board DSP test
(#1293)
MIN
ON
test board UUCSS
2818 (r)
Any
None
MIN
ON
test board UUCSS
3329 (s)
3
LANHO critical error
MAJ
OFF
3585 (t)
ATM Framer Looparound
test (#1260)
MAJ
ON
test board UUCSS l
3586 (t)
ATM Framer Looparound
test (#1260)
MAJ
ON
test board UUCSS l
3841 (u)
3842 (v)
3843 (w)
None
3999 (x)
Any
None
Any
32767
2
None
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
2.
Aux Data 32767 for any error log entry indicates that an alarmed ATM-EI was busied out and then released.
When this occurs, existing service-affecting alarms must be preserved. Typically, every alarm is resolved when
the ATM-EI is released. Therefore, the Alarm and Error Logs must be repopulated with the alarms present at
time of busyout. This Aux Data indicates that existing Error Type and Error Log time stamps are no longer valid
because they were lost when the circuit pack was released.
Table 8-80.
ATM-EI Error Log Entries —
Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...