![Avaya S8700 Series Скачать руководство пользователя страница 2296](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022296.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1574
Issue 1 May 2002
Layer 3 Query Test (#1243)
This test is nondestructive.
This test is used to check the application layer communications across the
in-service ISDN D channel. The test passes if a status enquiry message is
successfully sent, fails if the signaling link is down, and aborts if a query is already
running or there is an internal error.
4
FAIL
Received a status of Level 1 Pending Activation, the NT1 has a loss of power
indicating a problem with the NT1.
1. Follow the manufacturer-recommended repair procedures for the NT1.
2. Execute the test port UUCSSpp command and review the results of the
Level 1 Status Inquiry test to verify the repair.
PASS
This test indicates that Level 1 is activated or that software has taken the port
out of service.
Table 8-613.
Test #1243 Layer 3 Query
Error
Code
Test
Result
Description / Recommendation
1005
ABORT
The test aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, a modem pool member or Music on Hold). This error
can be ignored.
1019
ABORT
Test is already running.
1113
ABORT
The signaling link is down.
1. Use the test port UUCSSpp long command to clear any errors which
prevent establishment of the signaling link.
2. Examine the results of Test #626, which is executed with the command. If
this test aborts or fails, follow the repair procedure for the Signaling Link
Status test.
3. Escalate problem if BRI Layer 3 Query test continues to abort.
Continued on next page
Table 8-612.
Test #1242 Level 1 Status Inquiry —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...