Maintenance-Object Repair Procedures
555-233-143
8-884
Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. A Major or a Minor alarm may be logged with this error. A Major alarm is
raised when the total number of GPTD ports currently in service is less
than or equal to 1/2 of the threshold number administered via the change
system-parameters maintenance command. Otherwise, a Minor alarm is
raised. In either case, run the short test sequence on the alarmed GPTD
port and follow procedures for the individual test results.
b. The GPTD port lost its translation. Testing the GPTD port is sufficient to
reload its translation. If testing the GPTD port does not clear the error, then
replace the Tone Detector circuit pack containing the defective GPTD port.
c. This error indicates the GPTD port is having problems detecting
call-progress tones. If this error is logged constantly, replace the Tone
Detector circuit pack containing the defective GPTD port.
d. This Error Type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
Table 8-336.
General-Purpose Tone Detector Port (CPTR) Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1
17664
Tone Detector Audit/
Update test (#43)
MAJOR
MINOR (a)
ON
test port UUCSSpp r 2
18
0
busyout port UUCSSpp
WARNING
ON
release port UUCSSpp
130 (d)
None
WARNING
ON
test port UUCSSpp sh r 2
257 (b)
17666
Tone Detector Audit/
Update test (#43)
MAJOR
MINOR (a)
ON
test port UUCSSpp r 3
513 (c)
Any
Tone Detection
Verification test (#42)
MAJOR
MINOR (a)
ON
test port UUCSSpp r 3
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...