AN-LN-PT (Analog Line Port)
Issue 1 May 2002
8-105
555-233-143
1004
ABORT
A valid call seized the port during the test and aborted the test.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station extension command to determine the service
state of the port.
3. If the port is active, wait until it is idle before testing. Retry the command at
1-minute intervals up to 5 times.
4. If the test continues to abort, escalate the problem.
1005
ABORT
This test was aborted due to a configuration problem. The test is not applicable
for this type of analog port. This error can be ignored.
1018
ABORT
Administration has disabled the test. The default for the
Test?
field on the
station form is y. Determine why this field has been set to n on this station (this
may be due to the ringing application Test #48, which can be disturbing to
customer or terminal equipment).
1. To enable the test for a particular station being tested, enter change
station extension.
2. Change the
Test?
field on the station form to y.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
System resources required to run test are not available. This could be due to a
failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, escalate the problem.
Any
FAIL
This test can fail due to either on- or off-board problems. Off-board problems
include TDM-BUS faults, EXP-PN and EXP-INTF faults, and faults associated
with the Tone Detectors/Tone Generators. Clear every off-board problem
before replacing the board.
1. A TDM-BUS problem is usually the result of a faulty board connection to
the backplane, or bent pins on the backplane. Resolve any TDM-BUS
errors in the error log.
2. Resolve any EXP-PN and EXP-INTF errors in the error log.
3. Resolve any TONE-BD and/or TONE-PT errors in the error log.
4. Test the board when the faults from steps 1, 2, and 3 are cleared. Replace
the board only if the test fails.
PASS
The port is correctly using its allocated time slots. Investigate user-reported
troubles on this port by running other port tests, by examining station wiring, or
by inspecting the station.
Table 8-40.
Test #6 NPE Crosstalk Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...