Maintenance-Object Repair Procedures
555-233-143
8-1452
Issue 1 May 2002
120
FAIL
The SNI circuit pack cannot communicate with the SNI in slot 20 over the circuit
path.
1. Fix any on-board SNI-BD errors against this SNI and the SNI in slot 20.
Use display errors to find any SNI-BD errors and check display alarms
to see whether the errors have on-board alarms. Then follow the
associated repair procedures for SNI-BD.
2. Check the error log via display errors for other SNI circuit packs with
SNI-PEER error type 3841. If other SNI circuit packs have SNI-PEER
error type 3841, then replace the SNI in slot 20. Replacing an SNI may be
service interrupting. See
‘‘SNI-BD (SNI Circuit Pack)’’ on page 8-1429
for
the procedure for replacing an SNI.
NOTE:
If other SNI circuit packs do not have SNI-PEER error type 3841 errors,
the problem could be at either of the peer SNI boards. It is arbitrary as to
which SNI is replaced first. Proceed as follows:
3. Replace this SNI.
4. Replace the SNI in slot 20.
122
FAIL
The SNI circuit pack cannot communicate with its neighbor via the circuit path.
1. Fix any on-board errors (SNI-BD, EXP-INTF, and/or DS1C-BD) against the
components of this fiber link by using display errors and display alarms
and following the associated repair procedures. (Use the list fiber-link
command to find the fiber link associated with this SNI. The display
fiber-link command can then be used to find the endpoints of the fiber link
and the DS1C circuit pack locations if this fiber link has a DS1 Converter
complex administered.)
2. Enter display errors and follow the associated repair procedures for any
FIBER-LK entries for the fiber this SNI is administered on. Check list
fiber-link to determine the administered fiber.
3. If this fiber link has a DS1 converter complex administered, enter display
errors and display alarms and follow the associated repair procedures for
any off-board DS1C-BD or DS1-FAC entries for either of the DS1C boards
administered or for the DS1 facilities associated with either of the DS1C
boards administered.
4. Replace this SNI.
Table 8-576.
TEST #755 SNI Circuit Path Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...