Maintenance-Object Repair Procedures
555-233-143
8-300
Issue 1 May 2002
ATM Cross Talk Test (#1298)
This nondestructive ATM Cross Talk test makes sure that TDM time slots are
correctly allocated to connections. It is useful for diagnosing one-way or noisy
connections. The test fails if the TDM programmable logic and/or the interface to
the DSP is not operating properly. The test can take more than 10 minutes.
shows a diagram of this test, substituting “CES mode”
for “PNC mode.”
Table 8-132.
ATM Crosstalk Test (#1298)
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate required system resources.
1. Retry the command up to 5 times at 1-minute intervals.
1002
ABORT
Could not allocate time slots. Traffic could be heavy or time slots could be
out-of-service.
1. Identify and correct TDM-bus errors (if any) using the procedures in the
TDM-BUS (TDM Bus) MO.
2. Repeat the test up to 5 times at 1-minute intervals.
1003
ABORT
Could not allocate a tone receiver. Too few Tone Detectors installed or Tone
Detectors out-of-service.
1. Identify and correct any TTR-LEV (TTR Level) errors listed in the Error
Log.
2. Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
3. Retry the test up to 5 times at 1-minute intervals a maximum.
2000
ABORT
Test timed out.
2100
ABORT
Could not allocate required system resources
1. Retry the command 5 times at 1-minute intervals.
1962
ABORT
Every TALKER DSP is busy.
2302
ABORT
Inconsistent uplink message from the ATM-TRK circuit pack.
1. Retry the command up to 3 times at 1-minute intervals.
2752
ABORT
The circuit pack in this location is not a TN2305A/2306A.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...