![Avaya S8700 Series Скачать руководство пользователя страница 2182](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022182.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1460
Issue 1 May 2002
3. Use the status sys-link command and select the active EI in the
IPSI-connected EPN connected to the distant switch node being tested.
(This display will show the path from the IPSI-connected EPN and the
SNI-to-SNI fiber being used in this path.)
4. If the port network LEDs are lit and multiple SNI-to-SNI fibers connect to
this distant switch node, physically remove the SNI that is listed in this
path.
If not lit, check that the fiber connections to the EPN are consistent with the
administered fibers (list fiber-link) that do not light the LEDs as expected.
5. Use the status sys-link command to determine the new path from the
IPSI-connected EPN to the this distant switch.
6. Run the test led port-network command on an EPN connected to the
distant switch node and verify that the LEDs on the correct EPN are lit.
7. Repeat steps 4 – 6 until the last SNI-to-SNI fiber to this distant switch node
has been tested.
Table 8-579.
TEST #759 Configuration Audit
Error
Code
Test
Result
Description / Recommendation
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
2300
ABORT
The downlink message necessary to run this test could not be sent.
1. Retry the command at 1-minute intervals up to 3 times.
2301
ABORT
The software timer could not be set before sending the downlink message
necessary to run this test.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...