Maintenance-Object Repair Procedures
555-233-143
8-886
Issue 1 May 2002
1003
ABORT
The system could not allocate a Tone-Clock for the test connection. This may
be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the port
network where the test aborted. If so see the recommended procedures
for
‘‘TONE-BD (Tone-Clock Circuit)’’
2. If a new Tone-Clock has been inserted, allow about 1 minute for
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2006
ABORT
The active Tone-Clock circuit pack or a Tone Detector circuit pack may not be
functioning properly.
1. Test the active Tone-Clock circuit pack in the port network with the test
tone-clock UUC command and see
‘‘TONE-BD (Tone-Clock Circuit)’’
failures.
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
Retry the command at 1-minute intervals up to 5 times.
101–
122
FAIL
1. Run the short test sequence: test port UUCSSpp sh r 1.
2. If the problem persists, the system is still operating properly but system
capacity will be reduced. In order to restore the system performance to
normal, replace the tone detector circuit pack containing the defective
GPTD port.
1022
FAIL
Tone detection for the system is administered as part of a wideband
configuration, and the tone detector is not a TN420C (the only circuit pack with
this capability). GPTD ports on other types of tone detector circuit packs are
taken out of service since they cannot provide the administered function.
1. Change the tone-detection mode administered on the system-parameters
country-options form, or remove every circuit pack except TN420C tone
detectors from the system.
PASS
Tone Detection Verification is successful. The GPTD port is able to detect
every call-progress tone and perform level measurements of test tones.
Table 8-337.
Test #42 Tone Detection Verification Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...