![Avaya S8700 Series Скачать руководство пользователя страница 605](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102605.webp)
status health
Issue 1 May 2002
7-349
555-233-143
Output (for S8700 IP Connect)
If the value in the
Cabinet Layout
field on the Cabinet form is
rack-mount-stack, then the output looks like the following. S8700 IP Connect
configurations do not use PN maintenance boards or, therefore, emergency
transfer; so the
EmTr
field is NoEqp.
Field Descriptions
Major
Number of major alarms logged up to 2000
Minor
Number of minor alarms logged up to 2000
Warning
Number of warning alarms logged up to 2000
Trunks
Number of busied-out trunks
Stations
Number of busied-out stations
Others
Number of busied-out maintenance objects, excluding trunks and stations
Static
Percentage of CPU time currently dedicated to high priority items such as
the operating system, rounded to the nearest whole number
SM
Percentage of CPU time currently dedicated to system management or
periodic and scheduled maintenance, rounded to the nearest whole
number
If a large amount of periodic or scheduled maintenance testing is being
performed, this number can be high without affecting service.
CP
Percentage of CPU time currently dedicated to call processing, rounded to
the nearest whole number
Call processing has priority over system management and will draw
occupancy from the SM or IDLE categories.
Idle
Percentage of CPU time currently idle and available for use, rounded to the
nearest whole number
Active PNC
A-PNC or B-PNC – The currently active PNC or B-PNC
Locked - The PNC is locked via the set pnc command.
Auto - The system is controlling selection of the active PNC.
status health
OCC: St: 11% Sm: 0% Cp: 28% Idl: 61%
PNC: Simplex ALARMS:Maj: 0 Min: 4 Wrn: 13
Pwr: comm Sync:primary Logins:6 BUSYOUT:Trk: 0 Stn: 0 Oth: 0
Cab EmTr Maj Min Wrn PNC Cab EmTr Maj Min Wrn PNC
1 NoEqp 0| 4| 13 up
2 NoEqp 0| 0| 0 up
13 NoEqp 0| 0| 0 up
26 NoEqp 0| 0| 0 up
32 NoEqp 0| 0| 0 up
64 NoEqp 0| 0| 0 up
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...