ANL-24-L (24-Port Analog Line)
Issue 1 May 2002
8-73
555-233-143
Station Status and Translation Audits and
Updates Test (#36)
This test updates the analog port’s message lamp state (if it has one) and
translations with information in the software.
Table 8-30.
Test #36 Station Status and Translation Audits and Updates
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1004
ABORT
The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension.
2. Use the status station command to determine the service state of the
port.
3. If the port is active, wait until it is idle, and retry the command at 1-minute
intervals up to 5 times.
1005
ABORT
The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1006
ABORT
This port has been busied out by command, or taken out-of-service by the
failure of the NPE Crosstalk test.
1. Look in the Error Log for error type 18 (port busied out) for this port. If this
error is present, release the port with the release station extension
command, and run the test again.
2. Check the Error Log for error type 1025 (NPE crosstalk test failed) for this
port. If this error is present, investigate the errors associated with the NPE
Crosstalk test (#6).
3. Make sure that the terminal is connected and in service, and then retest.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
This does not indicate a hardware problem. The switchhook audit failed. The
other updates were not performed because of this failure. This may occur
when the audit is performed at the same time the terminal equipment goes
off-hook.
1. Use the status station command to determine when the port is available
and retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...