IPMEDPRO (IP Media Processor Circuit Pack)
Issue 1 May 2002
8-931
555-233-143
Notes:
a. Error Type 1—indicates that the circuit pack has been removed from the
system or is not fully administered. The alarm is logged about 15 minutes
after the circuit pack has been removed, or 11 minutes after the
SAKI
test
(#53) fails.
To be fully administered, a IPMEDPRO circuit pack must meet all of these
four conditions:
■
Have an entry in the circuit pack form (change circuit pack)
■
Have the MedPro IP address administered (change node-names)
■
Be enabled (change ip-interface)
■
Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit pack form and either of the
other two conditions are not met, a MINOR alarm is logged. To resolve the
error, either:
■
Make sure all conditions for administration are met and that a
functioning MedPro circuit pack is inserted in the correct slot.
■
Completely remove the IPMEDPRO from the system using the
following steps:
a. Remove the administered
IP-Interface
associated with the
circuit pack.
b. Physically remove the circuit pack from the slot.
c. Execute the remove medpro UUCSS and change circuit
pack UUCSS commands.
b. Error Type 18—The IPMEDPRO interface circuit pack has been busied
out by a busyout board UUCSS command.
1. Release the circuit pack (release board UUCSS).
1. Release the circuit pack (release board UUCSS).
c. Error Type 23—The IPMEDPRO circuit pack is not completely
administered. To be fully administered, an IPMEDPRO circuit pack must
meet all of these four conditions:
■
Have an entry in the circuit plan (change circuit pack)
■
Have the IPMEDPRO IP address administered (change
node-names)
■
Be enabled (change ip-interface)
■
Be physically inserted into the correct slot.
A DS1 (IPMEDPRO, MEDPRO, MAPD, UDS1-BD and DS1-BD) differs
from most circuit packs in that inserting the circuit pack into the switch is
not enough to make the board usable. It must also be administered.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...