test alarms
Issue 1 May 2002
7-417
555-233-143
Output
The responses, with normal output, will be displayed on a test-by-test basis with
one line of data displayed for each test result. With the failures option only the
tests that have failed will be displayed.
The following output fields are for the ALARM ENTRY section:
The following fields are displayed for the test results:
When errors are encountered preparing a particular object to be tested (not
inserted, contention, etc.) the an error message will be displayed. This error
message will be displayed in the TEST RESULTS data.
Port
The location of the alarmed object (cabinet-carrier-slot-circuit). This is the
same identifier as used by the alarm log.
Maintenance
Name
The logical name of the maintenance object which has been alarmed.
On Board
Whether the fault detected is on the associated circuit pack, or an off board
element connected to the circuit pack.
Alt Name
Terminal extension numbers or trunk-group numbers.
Alarm Type
Major, minor, or warning. This is an indicator to the seriousness of the
alarm raised.
Service State
RDY (ready for service), OUT (out of service), or IN (in service). This is the
current service state of the station and trunk ports shown.
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance object
that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the maintenance object. This field
contains the extension when the object is a station, and it contains xxx/yyy
when the object is a trunk, where xxx is the trunk group number and yyy is
the member number. It contains P/xxx when the object is a private CO line,
where xxx is the private CO line group number.
Test No
The actual test that is being executed.
Result
An indicator as to whether the test failed, passed, aborted or no hardware
was available (no board). If this field has conflict, this means that another
user was testing this hardware. If this field has epn-down it means that the
epn is inaccessible at this time.
Error Code
A numerical description of why the test failed or was aborted.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...