Error Log Entries and Test to Clear Values
Notes:
a. The CDR link is busied out. The CDR link is torn down.
b. Link Retry test (#215) fails. An error was detected when setting up the link.
See the preceding section
‘‘Procedures for Restoring the CDR Link’’
for
resolution.
c. The CDR physical link is down for one of the following reasons:
■
Cable to the CDR output device is disconnected.
■
CDR output device is powered off.
■
The data extension where the CDR output device connects to has
been busied out or there is a scheduled daily interchange.
Check the connectivity of wire and cable among wall jacket, data module,
and the CDR output device. Enter status data extension and verify that
the data extension of the CDR output device is in the in-service/idle state.
If the data extension is not available, see
‘‘Procedures for Restoring the
for resolution. Issue the display
system-parameters-maintenance command to see the start time of daily
maintenance. If the error occurs and is resolved during of daily
maintenance, it can be ignored.
d. This error indicates that the CDR output device is in an off-line state, (for
example, due to paper jam or paper out for a printer device). The CDR link
is torn down. Check the CDR output device and act promptly to put it back
to on-line state. Enter test cdr primary | secondary command to set up
the CDR link.
Table 8-534.
CDR Link Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test cdr primary | secondary sh
18 (a)
0
busyout cdr
primary|secondary
WARNING
OFF
release cdr primary | secondary
257 (b)
Any
Link Retry test (#215)
MINOR
2
WARNING
2.
Minor alarms may be downgraded to Warning alarms based on the value used in the set options command.
OFF
test cdr primary | secondary l
513 (c)
test cdr primary | secondary
1025 (d)
1281 (e)
Any
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...