Maintenance-Object Repair Procedures
555-233-143
8-1726
Issue 1 May 2002
j. Error Type 1300 — CSU module/T1 sync splitter missing or E1
synchronization splitter (E1SS) missing.
CSU module/T1 sync splitter missing: The
Near-End CSU Type
field
on the add ds1 form has been administered as
integrated
but the
120A1 CSU module or the 401A T1 sync splitter is not physically
connected (or is improperly connected) to the UDS1 board behind the port
carrier.
If using the 120A1 CSU module or the 401A T1 sync splitter, plug (or
replug) the CSU module/T1 sync splitter into the UDS1 circuit pack’s
connector on the I/O connector panel on back of the carrier. Otherwise,
change the
Near-End CSU Type
field using the change ds1 form to
other
.
If this error remains after plugging the CSU module/T1 sync splitter into the
board’s connector, there could be a problem with the I/O connector panel.
E1 synchronization splitter missing: The
E1 Sync-Splitter?
field
on the add ds1 form has been administered as
y,
but the 402A or 403A
E1 synchronization splitter is not physically connected (or is improperly
connected) to the UDS1 board behind the port carrier.
If using the 402A or 403A E1 synchronization splitter, plug (or replug) the
E1SS into the UDS1 circuit pack’s connector on the I/O connector panel on
back of the carrier. Otherwise, change the
E1 Sync-Splitter?
field
using the change ds1 form to
n
.
If this error remains after plugging the E1SS into the board’s connector,
there could be a problem with the I/O connector panel.
k. Error Type 1301 — CSU module/T1 sync splitter not expected or E1
synchronization splitter not expected.
CSU Module/T1 Sync Splitter not expected: The 120A1 CSU module or
the 401A T1 sync splitter is physically connected to the UDS1 board behind
the port carrier, but the
Near-End CSU Type
field on the add ds1 form
has not been administered as
integrated
.
If the 120A1 CSU module or the 401A T1 sync splitter is to be used, use
the change ds1 command to change the
Near-End CSU Type
field to
integrated
. Otherwise, physically remove the 120A1 CSU module or
the 401A T1 sync splitter from the back of the port carrier.
E1 synchronization splitter not expected: The 402A or 403A E1
synchronization splitter is physically connected to the UDS1 board behind
the port carrier, but the
E1 Sync-Splitter?
field on the add ds1 form
has not been administered as
y
.
If the 402A or 403A E1 synchronization splitter is to be used, use the
change ds1 command to change the
E1 Sync-Splitter?
field to
y
.
Otherwise, physically remove the 402A or 403A E1 synchronization splitter
from the back of the port carrier.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...