UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1797
555-233-143
Table 8-687.
Test #1214 One-Way Span Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS one-way-span-test-begin command at
1-minute intervals up to 5 times.
1005
ABORT
One-Way Span test cannot be executed in the current configuration. To run
this, the TN464F or later suffix UDS1 must be administered for 24-channel
operation. The “Bit Rate” field on the DS1 circuit pack administration form must
be set to “1.544” for 24-channel operation.
1015
ABORT
Ports on the UDS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put every trunk or port of
the UDS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABORT
The UDS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the UDS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the IPSI or Tone-Clock
circuit pack via the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loopback/span test is already executing on the DS1 board or the board
is in a network requested loop-back mode (line loopback or payload loopback).
The hardware error log will indicate whether a Customer Loop-Back Jack test,
Far CSU Loopback test, or the One-Way Span test is executing or if the board
is in line-loopback or payload-loop-back mode. Only one long-duration
loopback/span test can be active at a given time. Thus, if a loopback/span test
is already active, that test must be terminated using the test ds1-loop UUCSS
end-loopback/span-test command in order to execute this test.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...