Maintenance-Object Repair Procedures
555-233-143
8-22
Issue 1 May 2002
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port was put in use during the test.
1. Use the display port UUCSSpp to determine the voice port extension of
the port. Use the status station command to determine the service state
of the port. If the service state indicates that the port is active, wait until it is
idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on the primary channel. Some users may notice a
disruption in service. In extreme cases, the conferencing feature may not work
at all.
14
FAIL
The primary voice channel is not transmitting properly. User impact may range
from no noticeable effect to loss of use of this port.
15
FAIL
The control channel between the processor and the EMBEDDED AUDIX circuit
pack is not transmitting properly. User impact may range from no noticeable
effect to loss of use of this port.
16
FAIL
The secondary voice channel is not transmitting properly. User impact may
range from no noticeable effect to loss of use of this port.
None
FAIL
The test failed for reasons external to the EMBEDDED AUDIX circuit pack.
1. Run circuit pack tests to check the IPSI Tone Generator circuit or the Tone
Generator circuit pack and the IPSI Tone Detector circuit or Tone Detector
circuit pack by using the test board UUCSS s command.
2. Resolve any problems that are detected on the Tone Generator circuit or
Tone Detector circuit.
3. If both circuit packs are functioning properly and the test still fails, replace
the EMBEDDED AUDIX circuit pack (see caution at the beginning of this
section).
Table 8-8.
Test #13 Voice and Control Channel Local Loop Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...