TBRI-TRK (Trunk-Side ISDN BRI)
Issue 1 May 2002
8-1583
555-233-143
If no Maintenance/Test circuit pack exists, an outgoing test call over a trunk-side
ISDN-BRI facility is established over a high-speed data channel on the Network
Control (NETCON) circuit pack (DATA-BD).
Asynchronous Commands
NOTE:
Only one trunk can be tested in a given port network, until the test call is
canceled or completes.
Table 8-618.
Test #258 ISDN Test Call
Error
Code
Test
Result
Description / Recommendation
4
ABORT
There is a problem with the Processor Interface Link.
1. See the PI-LINK (Processor Interface Link) Maintenance documentation.
1004
ABORT
B channel in use.
1. Issue the status trunk command to determine whether a call is active on
this trunk-side ISDN-BRI channel.
2. When the service state indicates in-service/idle, retry the test.
1005
ABORT
Bad Configuration (that is, no Maintenance/Test circuit pack)
Issue the test trunk trunk-group/trunk-member command and make sure
there is a DATA-CHL (NETCON channel) administered.
1018
ABORT
Test call is disabled.
1. Enable Maintenance on the Trunk Group form.
1024
ABORT
(M/T-DIG) Maintenance/Test Digital Port in use.
1. Wait until yellow and green LEDs are turned off on the M/T-BD
(Maintenance/Test circuit pack).
2. Retry the test. If problem persists, see
Digital Port)’’ on page 8-1161
.
1113
ABORT
The signaling link has failed; the system cannot send any messages on behalf
of this trunk.
1. Check the results of Test #1251 (Signaling Link State Check Test).
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116
ABORT
The switch could not appropriately change the ISDN service state.
1. Issue the status trunk command to determine whether a call is active on
this trunk-side ISDN-BRI channel.
2. If not, check the error and alarm logs for problems with this TBRI-TRK MO.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...