BRI-SET, ASAI-ADJ, BRI-DAT
Issue 1 May 2002
8-359
555-233-143
The switch sent a message to the endpoint that did not respond in the
allotted time. This can happen occasionally due to failure of the
point-to-point signaling link or because of a problem in the BRI endpoint or
ASAI adjunct or Avaya adjunct. Execute the test station extension sh
command and pay particular attention to the results of the BRI Layer 3
Query test (#629). If this test fails, follow the repair procedure for Test
#629.
b. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, replace or
reinsert the circuit pack.
c. This error occurs when the endpoint does not respond to the service state
query message sent to the adjunct or the endpoint. This error causes an
alarm to be raised. The alarm is retired when the switch receives a
response to the service state query to the endpoint or the adjunct.
For BRI endpoints, the Aux Data field for this error contains “0.” When it
occurs, execute the test station extension sh command and pay
particular attention to the results of the BRI Layer 3 Query test (#629). If
this test fails, follow the repair procedure for Test #629.
When this error occurs for an ASAI or Avaya adjunct, the Aux Data field
indicates the state of the ASAI link or Avaya link and whether an invalid
response or no response was received to the query from the switch, as
shown in the following table:
See “Status BRI-Port” in
Chapter 7, ‘‘Maintenance Commands’’
, for an
explanation of the ASAI link states.
For ASAI or Avaya adjuncts, the switch automatically queries the adjunct
every two minutes (and therefore the Layer 3 Query test is not executed for
ASAI or Avaya adjuncts via a command issued from the G3MT terminal).
While alarmed for this error, the switch momentarily (for five seconds)
takes the associated port out-of-service every 15 minutes. This action is
taken in an attempt to stimulate recovery actions to be taken by the
adjunct.
Aux Data
ASAI Link State
Error
102
13-restarting
No response to RESTART message
104
13-restarting
Invalid response to RESTART message
152
13-restarted
No response to layer-3 query
154
13-restarted
Invalid response to layer-3 query
202
13-established
No response to layer-3 query
204
13-established
Invalid response to layer-3 query
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...