DIG-IP-STN (Digital IP Station)
Issue 1 May 2002
8-537
555-233-143
The terminal returns its configuration information and health information.
The information is checked, and a PASS/ABORT result is provided. If the
result is ABORT, an error is logged in the hardware error log (IP terminal
only)
.
Table 8-217.
Test #17 Station (Digital) Audits Test
Error
Code
Test
Result
Description / Recommendation
1
ABORT
Switchhook audit timed out.
2
ABORT
ID request fails, health bit returned from voice terminal is bad (IP Terminal
only).
1. Make sure voice terminal is connected, and repeat test.
2. If test fails, replace the voice terminal, and repeat test.
4
ABORT
Internal system error
1. Resolve any outstanding circuit pack maintenance problems.
2. Retry the command at 1-minute intervals up to 5 times.
5
ABORT
Ringer update aborted due to station being in ready-for-service or
out-of-service state.
6
ABORT
This port could have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error is present, then release the port via release station extension.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required for this test are not available.
2000
ABORT
Response to the test was not received in the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Station Audits passed.
1. If complaints persist, investigate by using other port tests, and by
examining the station, wiring, and connections.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...