Maintenance-Object Repair Procedures
555-233-143
8-132
Issue 1 May 2002
Table 8-49.
Test #210 140AY Loop-Around Test
Error
Code
Test
Result
Description / Recommendation
1–3
ABORT
Response to the test request was not received within the allowable time period.
The error code indicates at which speech compression rate the test aborted (1
being the first rate tested, 3 being the last).
1. Retry the command at 1-minute intervals up to 5 times.
10
ABORT
The PSMA (Playback Speech Memory Array) test (#206) failed on
Announcement Port 1.
90
ABORT
The PSMA (Playback Speech Memory Array) test (#206) failed on
Announcement Port 9.
1. Refer to “ANN-PT”, Test #206.
1000
ABORT
System resources required to run this test are not available. This test needs
Announcement Ports 1 and 9 to run. One of the ports may be active on a valid
call.
If Ports 1 and 9 are idle, retry the command at 1-minute intervals up to 5 times.
1002
ABORT
The system could not allocate time slots for the test. The system may be under
heavy traffic conditions or it may have time slots out-of-service due to
TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
retry the command at 1-minute intervals up to 5 times.
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be
oversized for the number of Tone Detectors present, or some Tone Detectors
may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 5
times.
1007
ABORT
The announcement circuit pack thinks that Port 1 or Port 9 is busy.
1024
ABORT
Announcement circuit pack blocked the test because an announcement
download is in progress. If a download is in progress, a status data-module
announcement data extension command should show that the announcement
data port is connected to a data line port that is part of a system access port,
and the removable media drive should be active (to determine the extension of
the announcement data module, use the list data-module command). See the
‘‘Locked Announcement Circuit Pack’’
at the end of the table for Test #209.
1. Wait until download is finished (up to 45 minutes), and then run the test
again.
2000
ABORT
Response to the test request was not received within the allowable time period.
If Error Type 1538 is present in the Error Log, follow the maintenance strategy
recommended for this error type.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...