![Avaya S8700 Series Скачать руководство пользователя страница 1794](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021794.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1072
Issue 1 May 2002
d. Error Type 125 - no Aux Data: The wrong circuit pack is inserted in the
slot where this circuit pack is logically administered.
1. Remove the wrong circuit pack and insert the logically administered
circuit pack
or
Re-administer this slot to match the circuit pack inserted (change
circuit-pack).
e. Error Type 257 - is associated with the Common Port circuit pack
maintenance test. See
‘‘XXX-BD (Common Port Circuit Pack)’’ on page
for details.
f. Error Type 1538 - is used to indicate hyperactivity on the circuit pack.
Hyperactivity on a circuit pack occurs when the angel is sending too many
CCMS messages uplink, 400 per ten seconds for the TN802B, to switch
software. The circuit pack will be taken out of service. See error Type
3999.
g. Error Type 2049 - indicates that the operating system is down. An attempt
is made to reset the board automatically. If the reset fails, the board is
probably bad and should be replaced.
h. Error Type 3841 - inconsistent downlink message. This error is not
service-affecting. No action is required.
i. Error Type 3999 - indicates that the circuit pack sent a large number of
control channel messages to the switch within a short period of time. If
Error Type 1538 is also present, then the circuit pack was taken
out-of-service due to hyperactivity. If Error Type 1538 is absent, then the
circuit pack was not taken out-of-service, but it has generated 50% of the
messages necessary to be considered hyperactive. This may be
completely normal during heavy traffic periods. However, if this error type
is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...