Maintenance-Object Repair Procedures
555-233-143
8-1618
Issue 1 May 2002
Standby Reference Health Check Test (#651)
This test evaluates the quality of the external synchronization timing source for a
standby IPSI or Tone-Clock circuit pack. Every administered synchronization
timing source must be valid for this test to pass. If the Tone-Clock circuit and the
synchronization timing sources are in different port networks, the EI circuit packs
transport the timing sources to the tone-clock.
Table 8-630.
Test #651 Standby Reference Health Check Test
Error
Code
Test
Result
Description / Recommendation
ABORT
This test may already be running due to a tone-clock installation, scheduled
maintenance, alarm activity, or a technician-demand test from another terminal.
This abort can also occur due to an internal system error.
1. Try the command again at 1-minute intervals up to five times.
1184
ABORT
This test requires an external synchronization source to be administered (DS1
primary, DS1 primary and secondary, or Stratum-3 clock).
1. Administer the external synchronization source and retry the test.
2500
ABORT
Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
0
FAIL
The external synchronization timing source for side A of the Stratum-3 clock or
for the primary DS1 reference is either absent or invalid. The external
synchronization timing source for side B of the Stratum-3 clock or the
secondary DS1 reference is not yet tested.
1
FAIL
The external synchronization timing source for side B of the Stratum-3 clock or
for the secondary DS1 reference is either absent or invalid.
1. Correct the synchronization source problem. See
Synchronization)’’ on page 8-1509
.
2. If the error still exists, replace the IPSI or Tone-Clock circuit pack reported
in the error log. See
‘‘Replacing the IPSI or Tone-Clock Circuit Pack’’ on
PASS
The external synchronization timing source is valid.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...