Maintenance-Object Repair Procedures
555-233-143
8-432
Issue 1 May 2002
1-3
FAIL
DTMF digits were not detected correctly. This may or may not impact reception
of R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system is still operating properly but capacity
will be reduced. To restore performance to normal, replace the call
classifier circuit pack containing the defective CLSFY-PT (Call Classifier
Port).
102
FAIL
2225-Hz Modem Answer tone was not detected correctly. This will impact
call-classification operation.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system can still operate properly but capacity
will be reduced. In order to restore performance to normal, replace the call
classifier circuit pack containing the defective port.
130
FAIL
Forward or backward R2-MFC signals were not correctly generated or
detected. This will impact R2-MFC calls.
1. Run the short test sequence via the test port UUCSSpp sh r 1 command.
2. If the problem persists, the system can still operate properly but capacity
will be reduced. In order to restore performance to normal, replace the call
classifier circuit pack containing the defective port.
PASS
Tone detection verification is successful. The call classifier port is able to
detect and generate every necessary tone.
Table 8-176.
Test #42 Tone Detection Verification Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...