Maintenance Commands
555-233-143
7-350
Issue 1 May 2002
Sync Source
The current source of timing signals used for system synchronization
For systems with a Stratum 3 clock:
External – Normal operating condition
Internal – Another source besides the Stratum 3 clock, such as a
Tone-Clock circuit or circuit pack, is providing the master timing signal.
For systems with Stratum 4 timing:
Primary – The primary administered timing source
Secondary – The secondary administered timing source
Local – Another source besides the administered ones, such as a
Tone-Clock circuit or circuit pack, is providing the master timing signal.
# Logins
Number of current users
Cab
Cabinet number
Cabinet numbers can be related to port network numbers with the list
cabinet command.
Emerg Trans
The current setting of the switches on the PN’s Maintenance circuit packs
that control Emergency Transfer. See EMG-XFER in
.
The following states are available:
Auto-
Emergency Transfer is under system control and is not
currently activated (normal operating state).
Auto+
Emergency Transfer is under system control and is in effect.
On
Emergency Transfer has been manually activated. This setting
should only be in effect during an emergency.
Off E
mergency Transfer is manually prevented from occurring. This
setting should only be in effect when a technician is on site.
na
The setting of the switch in this PN is not available to the switch.
The Expansion Archangel Link (EAL) may be down.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...