ATM-INTF (TN2305/6)
Issue 1 May 2002
8-231
555-233-143
Control Channel Loop-Around Test
This test queries the circuit pack for its circuit-pack code and vintage and verifies
its records.
Table 8-98.
Test #52: Control Channel Loop-Around
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
The response to the test request was not received within the allowable time
period.
2100
ABORT
The system resources required to this test are not available.
2500
ABORT
Internal system error — Retry the command at 1-minute intervals up to 5 times.
FAIL
The circuit pack failed to return the circuit pack code or vintage.
1. Retry the command up to 5 times.
2. If the problem continues, reset the circuit pack.
3. Retry the command up to 5 times.
PASS
Communication with this circuit pack is successful.
Any
NO
BOARD
This is normal if the test is being executed when:
1. The board is not physically in the system.
2. The system is booting.
Otherwise, there is some inconsistency in the date stored in the system.
1. Verify that the board is physically in the system.
2. Verify that the system is not in the process of booting.
3. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...