PKT-INT (Packet Interface)
Issue 1 May 2002
8-1249
555-233-143
■
Use status sys-link to identify the PKT-INT location in this PN, or
use status sys-link to find the PKT-INT hardware used by the
faulted link.
■
Then use test sys-link command to troubleshoot that component.
■
Issue the status packet-interface command to determine the:
— Service state of the Packet Interface circuit (for example, in
service/out of service)
— Total number of Packet Interface links assigned to a Packet
Interface circuit.
For a standby IPSI’s Packet Interface circuit in a high- or
critical-reliability system (duplicated IPSIs), the circuit (if not out of
service due to a failure condition) is shown in “standby” mode. The
number of links for a standby Packet Interface circuit is always zero.
In general, if every link for an active IPSI’s Packet Interface circuit is shown
as a “Failed Link,” there may be a fault on either the Packet Interface circuit
or the packet bus that caused every link to go down. If only a small
percentage of the links are shown as “Failed Links,” then the Packet
Interface circuit is probably not the source of the problem. Some typical
sources of individual link failures include a:
■
Failed BRI telephone set
■
Disconnected cord to a BRI set (causes three link failures)
■
Failed or removed EI circuit pack in an PN (causes one link failure)
For a case where not every link appears in the “Failed Links” category,
examine the alarm and error logs for failures of the following circuit packs,
and follow the repair procedures for those circuit packs before considering
replacing the associated IPSI circuit pack:
■
TN570 Expansion Interface circuit pack (EXP-INTF)
■
TN573 Switch Node Interface circuit pack (SNI-BD)
■
Switch Node Clock circuit pack (SNC-BD)
■
ISDN-BRI Line circuit packs, ports, and stations (BRI-BD,
BRI-PORT, BRI-SET)
■
Universal DS1 circuit packs and ports (UDS1-BD, TIE-DS1)
■
TN464C, TN2207, TN2464 Universal DS1 circuit pack
—
ISDN-PRI
service
■
TN556, TN2198, TN2185 ISDN-BRI Line circuit pack
—
ISDN-BRI
service
■
TN2305, TN2306 ATM
■
TN799DP Control LAN (C-LAN) packet port circuit pack
■
TN2501 Voice Announcements over the LAN (VAL)
Use the test sys-link command with the faulted path option to test all
components in the faulted link.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...