![Avaya S8700 Series Скачать руководство пользователя страница 2553](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022553.webp)
VAL-BD (Voice Announcements over LAN Circuit Pack)
Issue 1 May 2002
8-1831
555-233-143
Table 8-699.
Test #600 Congestion Query Test
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. Retry command at 1-minute intervals up to 5 times.
2. If the problem persists, reset the circuit pack (reset board UUCSS).
3. If the problem persists, replace the circuit pack.
2012
ABORT
Could not allocate the necessary system resources to run test.
2100
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the problem persists, escalate the problem.
1
2
FAIL
FAIL
The buffer level is nearly exhausted.
The VAL is congested, and no buffers are available.
1. Retry command at 1-minute intervals up to 5 times.
2. If command continues to fail, examine the VAL port measurements to
determine which ports are heavily utilized and the processor occupancy of
the circuit pack.
A Low processor occupancy when VAL is congested indicates circuit pack
failure.
1. If the problem persists, reset the circuit pack (reset board UUCSS).
2. If congestion recurs, replace the circuit pack.
High processor occupancy indicates the VAL is congested due to traffic load.
■
To relieve congestion in the short term, selectively busyout ports (busyout
port UUCSSpp) on the VAL circuit pack.
■
To achieve a more permanent resolution, it could be necessary reassign
announcements to other integrated announcement circuit packs.
Consider replacing affected VAL ports with new ports.
3
FAIL
The VAL circuit pack is not operating normally and is congested.
PASS
Hardware setting and attached cable type match VAL circuit pack
administration. The circuit pack detects no errors.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...