Maintenance-Object Repair Procedures
555-233-143
8-176
Issue 1 May 2002
Service State Audit Test (#256)
This test checks the service state of the trunk.
Country protocol 1.
If the interface uses country protocol 1 (includes USA), the
service-state audit executes in every trunk service state. It queries the service
state on the far end and waits 2 minutes for a reply. If the first request times out,
the service-state audit asks again. If the request times out again, it logs error
3073 and resends the request every 15 minutes. It places in-service trunks in the
MAINTENANCE/FAR-END state (outgoing calls blocked, incoming calls
accepted). Incoming calls trigger an immediate service-state audit without waiting
for the end of a 15-minute cycle.
Any other country protocol.
If the interface uses some other country protocol, the
service-state audit executes only on trunks that are in the
OUT-OF-SERVICE/FAR-END state. It asks the far-end switch to bring the trunk
back into the IN-SERVICE state and waits 2 minutes for a reply. If the first request
times out, the service-state audit asks again. If the request times out again, it
leaves the trunk in the OUT-OF-SERVICE/FAR-END state and tries again in 1
hour.
NOTE:
PASS for this test only means that a message to the far end was
successfully sent.
To check the service state of the ATM-BCH trunk, run status trunk grp#/mbr#.
Table 8-72.
Test #256 Service State Audit Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
Needed resources not available, port on a call or initializing
1. Run status trunk grp#/mbr#.
1. Check the results of Test #255.
1018
ABORT
Maintenance disabled
1. Enable maintenance by entering y in the
Maintenance Tests?
field
on page 2 of the change trunk-group form.
1113
ABORT
Signaling link failed
1. Run status trunk grp#/mbr#.
2. Check the results of Test #255.
3. See the
‘‘ATM-SGRP (ATM Signaling Group)’’
MO.
1114
ABORT
Signaling link in transitional state
1. Retry the command up to 5 times at 1-minute intervals.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...