ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 May 2002
8-291
555-233-143
ATM Board Error Query Test (#1259)
This nondestructive ATM Error Query test retrieves the most severe, active, on-
and off-board problem from the ATM-TRK circuit pack’s firmware and increments
error counts in the Error Log.
The test passes if there are no errors and fails otherwise. A passing test clears
the software counters; a failure increments the counter associated with the
problem that caused the failure and clears the others.
Table 8-126.
ATM Board Error Query Test (#1259)
Error
Code
Test
Result
Description / Recommendation
2000
ABORT
Test request timed out.
2031
ABORT
SCD failure. Unable to sent down-link message.
2100
ABORT
Could not allocate needed system resources.
2500
ABORT
Internal system error
1. Retry the command up to 3 times at 1-minute intervals.
XXYY
FAIL
On-board error XX (
) and/or off-board error YY (
1. Examine the error logs and repair any errors found.
PASS
The ATM circuit pack has passed this test. No service effecting errors/alarms
have been detected on board.
0
NO
BOARD
ATM-TRK circuit pack not found
1. Check the error log, and correct Error 125 (wrong board) or Error 131 (no
board), if found.
2. Make sure that the board is properly translated and inserted.
3. Check for hyperactivity (Error 1538). Run reset board UUCSS if
hyperactive.
4. Run the test again. If it fails, replace the board, and retest.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...