IP Address Query Test #1371
This test is destructive.
The Media Processor has two interfaces for configuring the board: through the
NT PC interface, and the SAT via CCMS messages. For R10 DoLAN, the SAT via
CCMS is the only approved interface. However, the NT PC interface cannot
easily be disabled. It is possible that changes can be made via the NT PC
interface that cause the Media Processor board to be inconsistent with S8700
Multi-Connect translations. The area of concern is the IP address, subnet mask,
and gateway translation.
This test sends the Media Processor the IP address, subnet mask, and gateway
translation (IP parameters). If the parameters do not match S8700 Multi-Connect
translations, the new values are written into the Windows registry, and the NT PC
asks the maintenance sub-system to reboot the board. The board goes through a
physical board removal and insertion.
When this test fails, it is an indication that an illegal change was made and the
customer should be notified. Also, writing the IP address parameters to the
registry requires NT to reboot. If the IP addresses match, there is no need to
update the registry and reboot NT.
Table 8-438.
Test #1371 IP Address Query Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABORT
Insufficient system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2801
ABORT
Unable to find IP address data for this location. Verify that the board is
administered.
2807
ABORT
The board is administered, but not enabled in the change ip-interfaces form.
FAIL
The IP address, subnet mask, and gateway translation parameters do not
match S8700 Multi-Connect translations. After the new values are written
into the Windows registry, the NT PC must go through a reboot. The board
goes through a physical board removal and insertion.
1. If the problem persists, replace the circuit pack.
PASS
Translation data matches the Windows Registry.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...