ISDN-TRK (DS1 ISDN Trunk)
Issue 1 May 2002
8-997
555-233-143
l. An ISDN trunk selected by the near end has been rejected 10 times by the
far end without a successful call. This may indicate a service-state
mismatch between the near and far ends for this trunk that is affecting the
end user (that is, customer receives unexpected intercept tones when
accessing ISDN trunks). This may indicate that the ISDN trunk is not
administered at the far end.
The Aux field contains the physical name of the ISDN trunk in decimal.
Then, verify that the far end has this trunk administered.
The Warning alarm will be retired automatically whenever an outgoing or
incoming call that uses this trunk is answered by the called endpoint. If
problems persist, then busyout the ISDN trunk to take it out of the hunt
group.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. For example, by clearing error codes associated with the
NPE Crosstalk test (#6), you may also clear errors generated from other tests in
the testing sequence.
Table 8-393.
System Technician-Demanded Tests: DS1-BD
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive, ND = nondestructive
NPE Crosstalk test (#6)
X
ND
Conference Circuit test (#7)
X
ND
Audit and Update test (#36)
X
X
ND
Signaling Link State Check test (#255)
X
X
ND
Service State Audit test (#256)
X
X
ND
Call State Audit test (#257)
X
X
ND
ISDN Test Call test (#258)
X
ND
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...