DS1 CONV-BD
Issue 1 May 2002
8-697
555-233-143
Removing Fiber Connectivity to an PN
This procedure covers removing the connectivity to an PN or between SNs.
Removing an PN and its associated carrier and circuit packs can be handled on a
board-type basis.
If this system is duplicated, start with step 1; otherwise, start with step 6.
NOTE:
The procedure below is generic in its scope. Check the customer’s switch
configuration for EI/SNI structures.
!
WARNING:
Do not power down a Switch Node carrier to replace a circuit pack.
!
WARNING:
In duplicated PNC configurations, one DS1-CONV complex in the fiber-link
serves as the active and the second DS1-CONV complex serves as the
standby. Each DS1Converter complex consists of two TN574 or TN1654
circuit packs.
Table 8-270.
Removing Fiber Connectivity to an PN
÷
#
Command/Step
Description
1.
status pnc
Verify that the A-side is active.
a. If the B-PNC is active, enter reset
pnc-interchange and press
Enter
.
b. Then verify that the A-side is active
(status pnc).
2.
busyout pnc standby
Busyout the duplicated switch side.
3.
change
system-parameters
duplication
Disable PNC duplication by changing the
Enable
Operation of PNC Duplication?
field to
n.
4.
list fiber link
List administered fiber connections by number.
Record the endpoints (EIs, SNIs, and DS1Cs), and
fiber link numbers that you are removing.
5.
busyout fiber link n
Busyout the fiber link of interest. The fiber link
number (step 4) is n for this command.
6.
remove fiber link n
Remove the link administration for this link.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...